You need two numbers: watts, meaning how much power runs at once, and kWh, meaning how much energy you use over the outage.

Watts = size

Add up the running watts of everything on at once, then add the biggest start-up surge. Fridges, pumps, and AC compressors briefly pull 2–3Γ— their running watts when they start.

kWh = how long

Watts Γ— hours Γ· 1,000. A 400 W load for 5 hours uses 2 kWh. Batteries are rated in kWh. Generators run as long as they have fuel.

Worked example 1: fridge + furnace fan + Wi-Fi, 24 hours

Worked example 2: CPAP with heated humidifier + Wi-Fi + phone charging, 1 night and day

About 1.48 kWh and 240 W peak. Look for a portable station with at least that much capacity; a 1 kWh unit would fall short of a full 24 hours. Check your CPAP's label for its exact watts.

Appliance wattage table

ApplianceRunning WStarting WDaily kWh note
Refrigerator150–400800–1200~1.0-2.0 (EST: 1/3 duty cycle) Estimate
Freezer100–500500–1000~0.8-1.5 (EST) Estimate
Furnace fan 1/2 HP300–800800–1600EST: running W x heating hours Estimate
Sump pump 1/3 HP500–8001000–1600EST ~3.8 at 20% runtime wet weather (outagemath.com) Estimate
Sump pump 1/2 HP800–10501300–2150EST ~5 at 20% runtime Estimate
Well pump 1/2 HP750–10001500–2000EST ~0.8 at ~1 hr/day (outagemath.com; 240V surge can reach 5,300W) Estimate
Well pump 1 HP1000–20002000–4000EST Estimate
Window AC 5,000 BTU450–600900–1200EST running W x hours Estimate
Window AC 10,000 BTU900–12001800–2400EST Estimate
Central AC 3 ton3000–35005000–6000EST Estimate
Electric range (one burner)1200–2400β€”EST Estimate
Microwave600–1200β€”EST Estimate
Space heater750–1500β€”EST Estimate
Electric water heater3000–4500β€”EST Estimate
Washing machine500–10001000–2300EST Estimate
TV 32-55in80–400β€”EST Estimate
LED bulb (each)8–15β€”EST Estimate
Phone/laptop charger20–100β€”EST Estimate
CPAP no heat30–60β€”EST ~0.24-0.48 for 8 h Estimate
CPAP heated humidifier60–120β€”EST ~0.5-1.0 for 8 h Estimate
Router/modem (Wi-Fi)10–20β€”EST ~0.24-0.48 (24 h) Estimate
Security system15–40β€”EST Estimate
Ceiling fan15–75β€”EST Estimate
EV Level 2 chargingno verified figureβ€”ESTIMATE - needs source (charger nameplate e.g. 7.2-11.5 kW) Estimate
Medical devices (oxygen concentrator etc.)no verified figureβ€”use device nameplate Estimate

Running and starting watts: Champion Power Equipment generator wattage chart, as of 2026-10-25. Daily kWh notes are our computed estimates. Some sump and well pump figures cite outagemath.com. A 240 V well pump can surge to 5,300 W, so check its nameplate.

Generator vs. battery

For a generator, match its running watts to your running total and its starting watts to your peak. Fuel takes care of the kWh. For a battery, you need both the watts and the kWh. We haven't verified generator prices yet, so we don't list any.

FAQ

What size generator do I need to run a refrigerator and furnace?

Using the Champion wattage chart, a fridge (400 W max running, 1,200 W start) plus a 1/2 HP furnace fan (800 W max running, 1,600 W start) and Wi-Fi need about 1,220 running watts and 2,020 peak watts, so a 2,500 W-class generator or power station covers it.

How many kWh do I need for a 24-hour outage?

For a fridge, a furnace fan running 8 hours, and Wi-Fi, our estimate is about 8.2 kWh, including the 0.85 usable-capacity assumption.